Product Details
Generac Corepower 7kW Air-Cooled Gas Engine Generator, Model 5837
Key Features:
- Digital LED Controller
- Automatic Transfer Switch with Built-In Priority Load Center
- Sound Attenuated Enclosure
- External Main Circuit Breaker
- Flexible Fuel Line Connector
- Natural Gas or LP Gas Operation
- UL 2200 Listed
NOTE: Designed Specifically For Units With 7KW Core Power Only
Features:
Engine
- Generac OHV engine
A durable, reliable powertrain for maximum power output
- Cast iron cylinder walls
Rigid construction and added durability provide long engine life
- Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time
- Pressurized filtration system
Better performance, less maintenance and significantly longer engine life
- Low oil pressure shutdown system
Superior shutdown protection prevents catastrophic engine damage due to low
oil
- High temperature shutdown
Prevents damage due to overheating
- Spin-on automotive type oil filter
Captures and collects harmful impurities with easy serviceability
Generator
- Revolving field
Allows for smaller, light weight unit that operates 25% more efficiently than
a revolving armature generator
- Displaced phase excitation
Maximizes motor starting capability
- Automatic voltage regulation
Regulates the output voltage to ±5% prevents damaging voltage spikes
- UL 2200 Listed
For your safety
Transfer Switch
- Fully Automatic
Transfers your vital electrical loads to the energized source of power
- Remote Mounting
Mounts near your existing distribution panel for simple, low cost installation
- Flush mountable
Can be installed in between studs like a standard electrical panel
- UL Listed
For your safety
Controls
- Manual/Auto/Off switch
Selects the operating mode
- Utility voltage sensing
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of
standard voltage
- Utility interrupt delay
Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds
- Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds
- Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute
- Seven day exerciser
Operates engine to prevent oil seal drying and damage between power outages
- Timed Trickle Battery charger
Maintains battery charge level to ensure starting
- Main Line Circuit Breaker
Protects generator from overload
Unit
- Weather protective enclosure
Ensures protection against mother nature. Tooless removal of roof and sides.
Three lift-out panels for easy access to all routine maintenance items
- Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries
- Small, compact, attractive
Makes for an easy, eye appealing installation
- SAE
Sound attenuated enclosure ensures quiet operation
Installation System
- 1' Flexible Fuel Line Connector
Easy Installation
Specifications:
Generator
- Rated Maximum Continuous Power Capacity (LP): 7,000 Watts
- Rated Maximum Continuous Power Capacity (NG): 6,000 Watts
- Rated Voltage: 240
- Rated Maximum Continuous Load Current – 240 Volts: 29.1 / 25
- Main Line Circuit Breaker: 30 Amp
- Phase: 1
- Number of Rotor Poles: 2
- Rated AC Frequency: 60Hz
- Power Factor: 1
- Battery Requirement (not included)
- Group 26R
- 12 Volts and 350 Cold-cranking
- Amperes Minimum
- Sound output in dB(A) at 23 ft. with generator operating at normal load:
67
Engine
- Type of Engine: GENERAC OHV
- Number of Cylinders: 1
- Displacement: 432cc
- Cylinder Block
- Aluminum w/Cast
- Iron Sleeve
- Valve Arrangement: Overhead Valve
- Ignition System: Solid-state w/Magneto
- Governor System: Mechanical
- Starter: 12 Vdc
- Oil Capacity Including Filter: Approx. 1.5 Qts./1.4L
- Operating RPM: 3,600
- Fuel Consumption
- Natural Gas
- cu.ft./hr.
- 1/2 Load: 83 (2.4)
- Full Load: 146 (4.1)
- Liquid Propane
- ft3/hr (gal/hr)
- 1/2 Load: 37.1 (1.02)
- Full Load: 47.6 (1.31)
- Required fuel pressure to generator fuel inlet at all load ranges
- 5 to 7 inches of water column for natural gas, 10 to 12 inches of
water column for LP gas
For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG)
Controls
- Digital LED Indicators: Simple user interface for ease of operation
- Mode Switch
- Auto: Automatic Start on Utility failure. 7 day exerciser
- Off: Stops unit. Power is removed. Control and charger still
operate.
- Manual/Test (start): Start with starter control, unit stays on.
If utility fails, transfer to load takes place
- Engine Start Sequence: Cyclic cranking: 16 sec. on, 7 rest (90 sec.
maximum duration)
- Engine Warm-up: 5 seconds
- Engine Cool-Down: 1 minute
- Starter Lock-out: Starter cannot re-engage until 5 sec. after engine
has stopped.
- 2.5 Amp Timed Trickle Battery Charger: Standard
- Automatic Voltage Regulator w/Overvoltage Protection: Standard
- Automatic Low Oil Pressure Shutdown: Standard
- Overspeed Shutdown: Standard, 72Hz
- High Temperature Shutdown: Standard
- Overcrank Protection: Standard
- Safety Fuse: Standard
Approximate Dimensions:
- Height: 33"
- Width: 30.2"
- Depth: 24.4"
Approximate Weight:
- Unit: 250 lbs
- Shipping: 280 lbs
Warranty Information:
- Manufacturer Warranty (authorized online retailer): 2 Years Parts
And Labor