Honeywell Home VISTA128BPT Light Commercial Burglary Alarm Control Panels
A proven, highly reliable solution, the VISTA-128BPT light commercial alarm panel supports burglary applications and a vast number of hardwire, V-Plex® and wireless options and features that maximize installation flexibility and simplify end-user operation. It is compatible with a wide range of AlarmNet® communications products for alarm reporting, uploading /downloading and remote services.
Features
- Provides nine style-B hardwired zones
- Supports up to 119 additional zones using a built-in polling (V-Plex®, multiplex) loop interface
- Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones)
- Provides one power-limited bell circuit delivering 1.7Amp (max) at 12VDC
- Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control
- Accommodates 150 user codes with seven authority levels
- Accommodates 32 keypad macro commands per system
- Keeps a log of up to 512 events
- Supports up to 16 compatible two-wire smoke detectors on zone 1
- Zone 7 may be used for keyswitch arming/ disarming
- Integrates with WIN-PAK® access control systems to provide increased users, event log and scheduling
- Supports V-Plex addressable VISTAKEY access control (up to eight doors and 250 cards)
- Easily programmed and maintained by Compass Windows-based downloader
- Supports up to 96 programmable outputs
- Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2010, order part number V128BPTSIA
- Supports up to six touchscreen Advanced User Interface (AUI) devices (6272 or later)
- Smoke detector reset at keypad
- Quick exit
- Group bypass
- Arm faulted
- Event arming
- Carbon monoxide (CO) zone type support
- Expanded high-speed RS-232 capability for third party interface and automation
- Internet upload/download over AlarmNet LTE and/or IP communicators over the panel’s keypad (ECP) bus
- Ringback support for AlarmNet communicators (confirmation of closing report)
- 24-hour dialer test support for AlarmNet devices
- Supports V-Plex Smart Contact feature for improved responsiveness on systems with many V-Plex zones
- Telco line cut detection
Basic Hardwired Zones
Provides nine style-B hardwired zones with the following characteristics:
- EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
- Individually assignable to one of eight partitions
- Up to 16 two-wire smoke detectors on zone 1
- Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device). Listed for residential fire only
Polling Loop Expansion
Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics:
- Must use V-Plex devices
- Supervised by control panel
- Individually assignable to one of eight partitions
- Supports VSI Module
- Supports 4297 Expander Module
- Maximum wiring distance = 12,000 feet
Wireless Expansion
Supports up to 127 wireless zones using up to two 5800 Series wireless receivers (fewer if using hardwire and/or polling loop zones).
- Wireless zones have the following characteristics:
- Supervised by control panel for check-in signals (except certain non-supervised transmitters)
- Tamper protection for supervised transmitters
- Individually assignable to one of eight partitions
Scheduling
Provides the following scheduling capabilities:
- Open/close schedules (for control of arming/disarming and reporting)
- Holiday schedules (allows different time windows for open/close schedules)
- Timed events (for activation of relays, auto-bypassing and unbypassing, autoarming and disarming, etc.) Access schedules (for limiting system access to users by time)
- End user output programming mode (provides 20 timers for output control)
Eight Partitions
Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include:
- A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed
- A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
- All zones assignable to one of eight partitions
- Keypads assignable to one of eight partitions or to Master partition 9 to view system status
- Ability to assign relays to one or all eight partitions
- Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option)
- Individually programmable account number, entry delay and exit delay by partition
|