The SurgeX Branch Circuit lineup provides guaranteed whole room surge protection and conditioning for audio, video, and mission critical equipment at the service panel. Available in two configurations, these solutions are built with NEMA magnetic shielding steel enclosures that meet code for use at the service entrance, sub-panels, and in ceiling plenums.
Engineered with Advanced Series Mode surge elimination and power conditioning technologies, they eliminate all surge energy to properly protect connected equipment from surges, spikes, and electrical transients without producing harmful ground contamination or common-mode disturbances. An all mode impedance tolerant EMI/RFI filter virtually eradicates electrical noise to offer a complete whole room power conditioning solution.
Specifications
- Load Rating: 20A (x4)
- Voltage Rating: 120V
- Power Requirement (no load): 4 W
- Surge Let-through Voltage (6000 Volt Surge): 0 Volts
- Maximum Applied Surge Voltage: 6000 Volts *
- Maximum Applied Surge Current: Unlimited (due to current limiting) *
- Maximum Applied Surge Energy: Unlimited (due to current limiting) *
- Endurance (C62.41-1991 category B3 pulses): 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
- EMI/RFI Filter
- Normal mode (50 ohm load): > 20 dB, 39 kHz – 50 MHz > 30 dB, 150 kHz – 50 MHz 25 dB @ 100 kHz; 45 dB @ 300 kHz; 67 dB @ 3 MHz; 35 dB @ 30 MHz
- Common Mode ( 50 ohm load): > 10 dB, 290 kHz – 50 MHz > 20 dB, 1.9 MHz - 7.875 MHz > 30 dB, 4.2 MHz – 5.125 MHz 10 dB @ 300 kHz; 17 dB @ 1 MHz; 30 dB @ 5 MHz; 14 dB @ 20 MHz
- Under-Voltage Auto Shutdown: No
- Over-Voltage Auto Shutdown: No
- Over-Current Auto Shutdown: None
- Over-Temperature Auto Shutdown: None
- Measurement Accuracy
- Voltage: NA
- Current: NA
- Power: NA
- Energy: NA
- Temperature: NA
- Network Port: No
- Serial Port: None
- Temperature Sensor Input: None
- Auxiliary Relay Outputs: No
- Contact Closure Input: No
- Temperature Range: 5C to 35C
- Humidity Range: 5% to 95% R.H. Non-condensing
- Agency Listings: Conforms to UL Std 1283 Certified to CSA Std C22.2 No. 8
* 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41 ** Specifications subject to change without notice
Approximate Dimensions
- Height: 16"
- Width: 12"
- Depth: 4"
Approximate Weight
- Unit: 30 lbs
- Shipping: 35 lbs
General
Approximate Weight
Approximate Dimensions
Frequently Asked Questions
-
This device uses Advanced Series Mode surge elimination technology, providing guaranteed whole room surge protection. It eliminates all surge energy to protect connected equipment from surges, spikes, and electrical transients without causing ground contamination or common-mode disturbances.
-
Yes, it includes power conditioning features with an all-mode impedance tolerant EMI/RFI filter that virtually eradicates electrical noise. This ensures cleaner and more stable power for audio, video, and mission critical equipment.
-
The unit is designed for use at service panels, including service entrance, sub-panels, and ceiling plenums. Its NEMA magnetic shielding steel enclosure meets code requirements for these installation locations.
-
It has a load rating of 20 amps per circuit at 120 volts, supporting up to 80 amps total, which is suitable for whole room surge protection applications.
-
Yes, it features a self-test circuit with a visual indicator to confirm proper functioning and readiness to protect your equipment from power surges.